Ecosine Max FN3470Ecosine Max FN3470

Ecosine Max Ecosine Max FN3470

Ecosine max, 400 VAC 50 Hz Full Performance Passive Harmonic Filters

Ecosine Max FN3470

Ecosine max, 400 VAC 50 Hz Full Performance Passive Harmonic Filters

  • Demonstrate best cost-performance ratio
  • Achieve 5% THDi for diode rectifier without DC-link choke and thyristor rectifier
  • Best-in-class partial load performance
  • Most compact open panel design for cabinet integration
  • Reliable and robust
  • Plug and play, ready to use

Features and Benefits

Schaffner ecosine harmonic filters represent an economical solution to the challenge of load-applied harmonics mitigation in three-phase power systems. With a plug-and-play approach and more compact dimensions than comparable products, they can be quickly installed and easily commissioned. They increase the reliability and service life of electric installations, help utilize electric sytem capacity better, and are the key to meet Power Quality standards such as IEEE 519. Ecosine filters reshape your distorted current back to the desired sinusoidal waveform. Schaffner ecosine filters can be applied to virtually any kind of power electronics with front-end six-pulse rectifiers, 3-phase diode or thyristor bridges, where harmonic current distortion needs to be reduced to defined limits.

Typical Applications

Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers

Technical Specifications

Nominal operating voltage

3 x 380 VAC to 415 VAC ±10%

Operating frequency

50 Hz ±1 Hz

Flammability corresponding to

UL 94 V-0

Nominal motor drive input power rating

250 to 500 kW

Total harmonic current distortion THDi*

<5% @ rated power for drives without Ldc

~3.5% @ rated power for drives equipped with 4% Ldc

Efficiency

>99% for rated voltage and power

Overload capability

1.6x rated current for 1 minute, once per hour

SCCR**

100 kA (UL approved)

High potential test voltage

P -> E 2520 VAC (1s)

Overvoltage category

OV III (IEC 60664-1)

Earthing System

TN, TT, IT

Protection category

IP 00

Cooling

External cooling***

Ambient temperature range

–25°C to +40°C fully operational

+40°C to +70°C derated operation****

–25°C to +85°C transport and storage

Design corresponding to

Filter: UL 61800-5-1, EN 61800-5-1

Chokes: EN 60076-6

* System requirements: THDv <2%, line voltage unbalance <1% Note: performance specifications in this brochure refer to six-pulse diode rectifiers. SCR rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors. ** External UL-rated fuses required. Please consult the user manual. *** Please check the inlet air flow required for cooling table further in this document and the user manual. **** Iderated = Inominal*SQRT((Tmax-Tamb)/(Tmax-Tnominal)) = Inominal*SQRT((70°C-Tamb)/30°C)

Typical electrical schematic

Ecosine Max FN3470

Approvals & Compliances

RoHS Label
UL Recognized Label (USA)
CE Label
UKCA Label
Back