FN2020FN2020

Standard Performance Single-Phase Filters FN2020

General Purpose AC/DC EMI Filter

FN2020

General Purpose AC/DC EMI Filter

  • Rated currents from 1 to 60 A
  • High differential-mode attenuation
  • Optional medical version (B type)
  • Optional safety version (A type)

Articles

Article Rated Current @ambient Leakage current IEC60939 Power Loss Inductance Capacitance Resistance Input/Output connections (Nm) Distribution stock Compare Read More
L1 Cx1 (µF) Cy1 (nF) Input terminal Output terminal
FN2020-10-06 FN2020-10-06 100.662.90.80.154.7100053 - STB16 16mm2APAC
FN2020-10-07 FN2020-10-07 100.662.90.80.154.7100056 - JTB M8 screw terminalPartner
FN2020-1-06 FN2020-1-06 10.660.8120.154.7100053 - STB16 16mm2APAC
FN2020-1-07 FN2020-1-07 10.660.8120.154.7100056 - JTB M8 screw terminalPartner
FN2020-12-06 FN2020-12-06 120.663.60.70.154.7100053 - STB16 16mm2APAC
FN2020-12-07 FN2020-12-07 120.663.60.70.154.7100056 - JTB M8 screw terminalPartner
FN2020-16-06 FN2020-16-06 160.662.50.650.154.7100053 - STB16 16mm2APAC
FN2020-16-07 FN2020-16-07 160.662.50.650.154.7100056 - JTB M8 screw terminalPartner
FN2020-16-08 FN2020-16-08 160.662.50.650.154.7100061 - M4 screw terminal blockRepresentative
FN2020-20-06 FN2020-20-06 200.663.80.60.154.7100053 - STB16 16mm2APAC
FN2020-20-08 FN2020-20-08 200.663.80.60.154.7100061 - M4 screw terminal blockRepresentative
FN2020-30-08 FN2020-30-08 300.796.30.670.471047061 - M4 screw terminal blockRepresentative
FN2020-3-06 FN2020-3-06 30.661.22.50.154.7100053 - STB16 16mm2APAC
FN2020-3-07 FN2020-3-07 30.661.22.50.154.7100056 - JTB M8 screw terminalPartner
FN2020-60-24 FN2020-60-24 600.7914.711.51022072 - M5 screw connector24 - M6 screw terminal
FN2020-6-06 FN2020-6-06 60.661.510.154.7100053 - STB16 16mm2APAC
FN2020-6-07 FN2020-6-07 60.661.510.154.7100056 - JTB M8 screw terminalPartner
FN2020A-10-06 FN2020A-10-06 100.072.90.80.150.47100053 - STB16 16mm2APAC
FN2020A-10-07 FN2020A-10-07 100.072.90.80.150.47100056 - JTB M8 screw terminalPartner
FN2020A-20-06 FN2020A-20-06 200.073.80.60.150.47100053 - STB16 16mm2APAC
FN2020A-20-08 FN2020A-20-08 200.073.80.60.150.47100061 - M4 screw terminal blockRepresentative
FN2020A-30-08 FN2020A-30-08 300.076.30.670.470.4747061 - M4 screw terminal blockRepresentative
FN2020A-60-24 FN2020A-60-24 600.0714.711.50.4722072 - M5 screw connector24 - M6 screw terminal
FN2020B-10-06 FN2020B-10-06 1002.90.80.15100053 - STB16 16mm2APAC
FN2020B-1-06 FN2020B-1-06 100.8120.15100053 - STB16 16mm2APAC
FN2020B-12-06 FN2020B-12-06 1203.60.70.15100053 - STB16 16mm2APAC
FN2020B-16-06 FN2020B-16-06 1602.50.650.15100053 - STB16 16mm2APAC
FN2020B-20-06 FN2020B-20-06 2003.80.60.15100053 - STB16 16mm2APAC
FN2020B-20-08 FN2020B-20-08 2003.80.60.15100061 - M4 screw terminal blockRepresentative
FN2020B-30-08 FN2020B-30-08 3006.30.670.4747061 - M4 screw terminal blockRepresentative
FN2020B-3-06 FN2020B-3-06 301.22.50.15100053 - STB16 16mm2APAC
FN2020B-60-24 FN2020B-60-24 60014.711.522072 - M5 screw connector24 - M6 screw terminal
FN2020B-6-06 FN2020B-6-06 601.510.15100053 - STB16 16mm2APAC

Features and Benefits

FN 2020 filters are designed for easy and fast chassis mounting
FN 2020 B versions without capacitors to earth comply to 1MOP for ME (medical equipment) acc. IEC 60601-1 
FN 2020 A versions with low capacitance to earth for safety critical applications with necessity for low leakage currents
All filters provide a general purpose conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior
FN 2020 filters can be used to cover a broad range of usage and they offer a good size/amperage ratio
FN 2020 filters are also available as two- stage filters (FN 2060, FN 2070 series) for more noisy environment
Various terminal options allow you to select the desired connection style

Typical Applications

Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Office automation equipment
Datacom equipment

Technical Specifications

Rated voltage*

250 VAC, 50/60 Hz

250 VDC

Operating frequency

DC to 400 Hz

Rated currents

1 to 60 A @ 40°C max

High potential test voltage

P –> N 1100 VDC for 2 sec (30 and 60 A types)

P –> PE 2000 VAC for 2 sec

P –> PE 2500 VAC for 2 sec (B types)

P –> N 760 VAC for 2 sec (1 to 20 A types)

Temperature range (operation and storage)

-25°C to +100°C (25/100/21)**

Certified to

UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to AC and DC applications)

Flammability corresponding to

Laces for -07 version: UL 94 VW-1

Terminal plastic for -06/-08 version: UL 94 V-0

Grommet for -07 version: UL 94 V-0

Design corresponding to

UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939

Overvoltage category

II acc. IEC 60664-1

Pollution degree

2 acc. IEC 60664-1

Altitude

2000m (above derating applies)**

* maximum RMS operating voltage at rated frequency or the maximum DC operating voltage ** for dedicated requests exceeding this specification (e.g. -40 °C or higher altitude) please contact your local Schaffner Sales office

Typical electrical schematic

FN2020

Approvals & Compliances

UL Recognized Label
CSA Label
ENEC 14 Label
CQC Label
RoHS Label
CE Label
UKCA Label