Product Overview
Downloads
Versatile Filtered Power Entry Module
- Rated currents up to 6 A
- Single or dual-fuse holder
- Fuses Ã6.3 x 32 mm Ã5 x 20 mm
- 2-pole rocker switch
- General purpose application
- Optional medical versions (B type)
Features and Benefits
Good conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior
Typical Applications
Portable electrical and electronic equipment
Technical Specifications
Maximum continuous operating voltage
250 VAC, 50/60 Hz
Operating frequency
50 to 400 Hz
DC to 400 Hz
Protection category
IP 40 according to IEC 60529
Temperature range (operation and storage)
-25°C to +85°C (25/85/21)
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to
UL 94 V-2 or better
Function
2-pole, dark not illuminated
Marking I - 0
Electrical specifications
Inrush current 51 A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life
50,000 cycles
Switch ratings
 
Europe (ENEC)
6 A (4 A), 250 VAC*
USA (UL)
6 A, 125 VAC
4 A, 250 VAC
1/10 HP
Canada (CSA)
6 A, 125 VAC
4 A, 250 VAC
1/10 HP
Rated currents
2 to 6 A @ 40°C max
High potential test voltage
P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 760 VAC for 2 sec
* Value in () relates to the inductive current charge: cos(phi) = 0.65